Overview This manual explains how to install and operate the Metrici Nano Station — a compact player that connects to any TV, monitor or display through HDMI and shows live parking information from the Metrici Web Interface. It covers the hardware and its ports, first boot, the main display page, the password-protected admin panel and the settings you need in the Metrici Web Interface to drive the screen.

Introduction

The Metrici Nano Station turns any screen with an HDMI input — a TV, a computer monitor, a professional signage display or a large-format screen — into a live parking information sign. It reads the Display Text configured in the Metrici Web Interface (for example total, free and occupied parking spaces) and shows it full screen, with each line in its own colour and the Metrici logo at the top — see Fig.1 Main Page.

The device is built on a Raspberry Pi Compute Module housed in the official metal Raspberry Pi IO Case. Because you choose the screen, the same Nano Station can drive a small monitor at a pay station or a large TV at a car-park entrance.

Nano Station or RGB LED Display?

Metrici offers two ways of showing the same Web Interface data. Both read the same Display Text and the same display URLs, so a location can be switched from one to the other without changing anything in the Web Interface.

Metrici Nano StationMetrici RGB LED Display
ScreenAny HDMI TV, monitor or display you chooseBuilt-in RGB LED matrix (64 × 32 or 128 × 64 pixels)
InstallationIndoor, next to or behind the screenIndoor or outdoor, IP66 aluminium housing
ContentDisplay Text from the Metrici Web Interface, or fixed textDisplay Text from the Metrici Web Interface, or fixed text
ConfigurationOn the connected screen — click or tap the Metrici logo 8 times to open the password-protected admin pageBrowser-based configuration on port 3000, from any device on the network

For the LED version, see the Metrici RGB LED Display manual.

Typical Applications

Technical Data

SpecificationDetails
DescriptionCompact HDMI player for Metrici parking and counting information
EnclosureRaspberry Pi IO Case — two-piece sheet-metal enclosure with built-in, speed-controlled cooling fan
Video output2 × full-size HDMI 2.0 (either port can be used)
USB2 × USB 3.0 Type-A
Networking1 × Gigabit Ethernet (RJ45); DHCP by default, static IP configurable
PowerUSB-C, 5 V / 5 A (27 W)
Dimensions170 × 94 × 28 mm
Content sourcesExternal URL (display URL from the Metrici Web Interface, HTTP or HTTPS) or Internal text typed on the device
TextUp to 3 lines, 7 colours (red, green, yellow, white, blue, cyan, magenta)
SoftwareVersion 3.0
ConfigurationPassword-protected admin page on the connected screen, opened by clicking or tapping the Metrici logo 8 times; USB mouse or touchscreen, on-screen keyboard included
InstallationIndoor use, in a ventilated location

Ports & Connectors

All connectors are reached through the cut-outs in the side of the case. No connection requires opening the enclosure.

ConnectorQtyUse
HDMI2Video output to the screen. Connect the screen to either HDMI port — both work.
USB 3.0 Type-A2USB mouse (or the USB touch cable of a touchscreen) for configuring the device on the connected screen. A keyboard is optional — the login page has an on-screen keyboard.
Ethernet (RJ45)1Network connection to the Metrici server that provides the display data. The device obtains its IP address by DHCP.
USB-C1Power input (5 V / 5 A).
microSD slot1Reserved for service. Do not remove or replace the card unless instructed by Metrici support.
Note: The case has ventilation openings for its internal fan. Keep them unobstructed — do not seal the Nano Station inside a closed box or press it flat against the back of a screen without an air gap.

1. How Does It Work

The Nano Station does not calculate any values itself; it displays what the Metrici Web Interface publishes. The chain is:

  1. Metrici Web Interface — a module such as Parking for LPR keeps track of the location (total spaces, vehicles inside, free spaces).
  2. Display Text — in the location settings you decide what the screen should show, line by line, using colour codes and data codes (e.g. #GFREE: #FSPACES).
  3. Display URL — the Web Interface publishes the result at an auto-generated address such as http://<METRICI_SERVER_IP>/io/lpr/location_display.php?id=1.
  4. Nano Station — reads this URL at the configured refresh rate and draws the text full screen on the HDMI display.

When no Metrici server is involved, the Nano Station can instead show fixed text configured on the device itself (the Internal text source, see Section 5.2 – Display Settings).

2. Getting Started

2.1 Installation

  1. Mount the screen and place the Nano Station close to it — for example behind the TV or in a nearby ventilated cabinet — within reach of the HDMI cable.
  2. Connect an HDMI cable from the Nano Station to the screen and select that HDMI input on the screen.
  3. Connect the Ethernet cable to a network with a DHCP server, from which the Metrici server is reachable. The Nano Station obtains its IP address automatically.
  4. If the screen is not a touchscreen, connect a USB mouse to one of the USB ports — you need it to open and use the admin panel. For a touchscreen, connect its USB touch cable instead.
  5. Connect the USB-C power supply last. The Nano Station starts up and opens the main display page full screen automatically.
Tip: Connect and switch on the screen before powering the Nano Station, so that the screen's resolution is detected correctly at start-up.

2.2 Opening the Admin Panel

The Nano Station is configured directly on the screen it is connected to:

  1. Wait until the main page is shown on the screen.
  2. Click (with the USB mouse) or tap (on a touchscreen) the Metrici logo at the top of the screen 8 times — marked 1 in Fig.1 Main Page.
  3. The Admin Login page opens. Enter the admin password (default: metriciadmin) — see Section 4 – Admin Login.

No physical keyboard is needed: the login page includes an on-screen keyboard.

2.3 Network

The Nano Station comes configured for DHCP: it receives its IP address automatically from the network it is connected to. If the installation requires a fixed IP address, switch to Static IP in the admin panel — see Section 5.1 – Network Settings.

We recommend changing the default password immediately after the first login, to prevent unauthorised changes to what the screen displays. See Section 5.3 – Security Settings.

3. Main Page

Nano Station main page showing TOTAL 5001 in white, FREE 3241 in green and BUSY 1760 in red, with the Metrici logo at the top marked 1
Fig.1 Main Page – Live Parking Display

The main page is what the Nano Station shows on the connected screen during normal operation — see Fig.1 Main Page.

The example in Fig.1 is produced by the Display Text shown in Fig.10 Parking for LPR: a location with 5001 parking spaces and 1760 cars inside, leaving 3241 spaces free.

4. Admin Login

Admin Login page with password field, Login button, Show/Hide Keyboard button and Back to Main Page link
Fig.2 Admin Login

The Admin Login page opens after you click or tap the Metrici logo 8 times on the main page (see Section 2.2). Access to the admin panel is protected by a single admin password — see Fig.2 Admin Login. There is no username field.

5. Admin Panel

After logging in you reach the Admin Dashboard. The software version and build date are shown next to the title (for example v3.0 - 20261021). The dashboard is divided into panels for the network, the display content, the admin password, system management and the activity log. The ← Back to Main Page link at the bottom of the page returns to the live display.

5.1 Network Settings

The Network Settings panel shows how the Nano Station is connected and lets you switch between DHCP and a static IP address — see Fig.3 Network Settings – DHCP and Fig.4 Network Settings – Static IP.

Network Settings (Live Configuration) panel with Network Mode set to DHCP: current live configuration at the top, then Network Mode, Network Interface and Connection UUID numbered 1 to 3, and the Apply Network Settings button
Fig.3 Network Settings – DHCP

Current Live Configuration

The upper part of the panel shows the values the device is using right now:

As the note in the panel explains, these values are read live from the system. Network settings are applied through NetworkManager rather than stored in the Nano Station's settings database, and they are kept after Reboot System or a power cut.

DHCP

DHCP is the factory setting. With Network Mode set to DHCP, only three fields are shown — see Fig.3 Network Settings – DHCP:

To go back to DHCP from a static address, select DHCP and click Apply Network Settings.

Network Settings panel with Network Mode set to Static IP: fields Network Mode, Network Interface, Connection UUID, IP Address, Netmask, Gateway and DNS Servers numbered 1 to 7, and the Apply Network Settings button
Fig.4 Network Settings – Static IP

Static IP

Select Static IP in Network Mode (1) and four more fields appear — see Fig.4 Network Settings – Static IP. Fields 2 and 3 work as described for DHCP.

Click Apply Network Settings, then check the Current Live Configuration to confirm the new values. The static address is kept after a restart or a power cut.

Important: Before applying a static IP, make sure the address is not used by another device and is in the same subnet as the gateway. Otherwise the Nano Station cannot reach the Metrici server and the screen stops updating.

5.2 Display Settings

The Display Settings panel defines what the main page shows. The upper part, Current Configuration, shows what is saved and what the screen is doing; the form below it changes the settings.

Display Settings panel with Content Source set to External URL (central API): current configuration with status, preview and last payload, then Content Source, Content URL and Refresh Rate numbered 1 to 3, Save Display Settings (4) and Test Connection (5)
Fig.5 Display Settings – External URL

Current Configuration

External URL (central API)

Use this source to show live data from the Metrici Web Interface — see Fig.5 Display Settings – External URL.

Display Settings panel with Content Source set to Internal text (typed here) (1) and the Internal Text field (2) containing #RMetrici, #YAccurate and #BRecognition on three lines
Fig.6 Display Settings – Internal text

Internal text (typed here)

Use this source to show fixed text without a Metrici server — see Fig.6 Display Settings – Internal text.

Every saved change is recorded in the Admin Activity Logs as a DISPLAY_SETTINGS entry, together with the new source, URL or text, and refresh rate.

5.3 Security Settings

Security Settings panel with New Admin Password field and Update Password button
Fig.7 Security Settings

The Security Settings panel changes the admin password used on the login page — see Fig.7 Security Settings. The Nano Station ships with the default password metriciadmin; change it after the first login.

Important – Save your new password in a safe place!
Write the new password down or store it in a password manager before logging out. If the password is lost, contact Metrici support at support@metrici.ro.

5.4 System Management

System Management panel with red Reboot System button
Fig.8 System Management

The red Reboot System button restarts the Nano Station — see Fig.8 System Management. During the restart the screen goes blank or shows the start-up sequence; after a short time the main page opens again automatically with the saved settings.

Important: Do not disconnect the power while the device is restarting. Wait until the main page appears on the screen again before opening the admin panel.

5.5 Admin Activity Logs

Admin Activity Logs panel listing DISPLAY_SETTINGS entries with details, admin user and IP, and a Clear All Logs button
Fig.9 Admin Activity Logs

The Admin Activity Logs panel keeps a history of the changes made from the admin panel, newest first — see Fig.9 Admin Activity Logs. Each entry shows:

Scroll inside the panel to see older entries. The Clear All Logs button deletes every entry in the list.

Tip: The Details line is the quickest way to check which URL or text was saved last, and when.

6. Web Application Integration

When the Display Settings content source is External URL, the content of the screen is generated by a module of the Metrici Web Interface (Parking for LPR, Parking Place Detector, Area Counter, Line Counter). For each module you have to do two things:

  1. In the Web Interface, fill in the Display Text field with the codes that describe what should appear on the screen.
  2. Copy the auto-generated URL shown under the Display Text field and paste it into the Content URL field of the Nano Station (see Section 5.2 – Display Settings), replacing IP_OF_THIS_SERVER with the address of your Metrici server.

The Display Text uses two kinds of codes: colour codes (# followed by a letter) and data codes (# followed by the name of the value). Write each line of the screen on its own row of the Display Text field, starting with its colour code.

The Web Interface sends the result to the Nano Station as one text that starts with #BEGIN, followed by one entry per line — for example #BEGIN#WTOTAL: 5001#GFREE: 3241#RBUSY: 1760. You can see exactly what was received in the Last Payload field of the Display Settings panel.

6.1 Colour Codes

Each line starts with a colour code: # followed by the initial of the colour. The Nano Station recognises the following colours:

Important: The Nano Station shows up to 3 lines. An entry that starts with any other letter is shown in white exactly as typed, including that letter. The Web Interface help text also lists orange (#O), indigo (#I) and violet (#V) for the RGB LED Display; on the Nano Station these lines appear in white with the letter in front (for example #OFree is shown as OFree). For a Nano Station, use only R, G, Y, W, B, C and M.

A number from 1 to 9 may be appended to a data code to define how many characters are reserved for that value (for example, #COUNTER3 reserves three characters).

6.2 Parking Module for LPR

Parking for LPR – Edit parking settings page with the Display Text field and the auto-generated display URL
Fig.10 Parking for LPR – Display Text configuration

In the Web Interface navigate to Parking for LPR → Settings, select the location and click Edit Parking Settings. Fill in the Display Text field (marked 1) — see Fig.10 Parking for LPR.

The data codes available for the Parking module are:

Example — the Display Text that produces the screen in Fig.1 Main Page:

#WTOTAL: #TSPACES
#GFREE: #FSPACES
#RBUSY: #BSPACES

The total comes from the Parking Spaces field and the occupied count from Cars inside on the same page; the free count is the difference between them.

The auto-generated URL has the form:

http://IP_OF_THIS_SERVER/io/lpr/location_display.php?id=1

Copy this URL into the Content URL field of the Nano Station and click Save in the Web Interface. For full details refer to the Parking Module for LPR – Settings chapter of the Metrici Web Interface manual.

6.3 Area Counter

Area Counter – Edit Location page with the Display Text field, the list of available codes and the auto-generated display URL
Fig.11 Area Counter – Edit Location

In the Web Interface navigate to Area Counter → Settings → Locations & Cameras, select the location and click the blue Edit button. Fill in the Display Text field — see Fig.11 Area Counter.

The data codes available for the Area Counter module are:

Example:

#YCapacity: #CAPACITY
#RBusy: #COUNTER
#GAvailable: #AVAILABLE

The auto-generated URL has the form:

http://IP_OF_THIS_SERVER/io/ac/location_display.php?id=1

The same Display Text mechanism can also be applied at the Group level (a group is a collection of zones sharing a characteristic). For full details refer to the Area Counter – Settings chapter of the Metrici Web Interface manual.

6.4 Line Counter

Line Counter – Edit Zone page with the Name and Display Text fields, the list of available codes, the auto-generated display URL and the counter and capacity fields for each object class
Fig.12 Line Counter – Edit Zone

In the Web Interface navigate to Line Counter → Settings, select the location and the zone you want to edit, then click Edit Zone. Fill in the Display Text field — see Fig.12 Line Counter.

The data codes available for the Line Counter module are:

Example:

#RInside: #COUNTER
#GAvailable: #AVAILABLE

The auto-generated URL has the form:

http://IP_OF_THIS_SERVER/io/lc/zone_display.php?id=17

For full details refer to the Line Counter – Settings chapter of the Metrici Web Interface manual.

6.5 Parking Place Detector

Parking Place Detector – Edit Location page with a three-line Display Text, the list of available codes, the auto-generated display URL and the emplacement schematic
Fig.13 Parking Place Detector – Edit Location

In the Web Interface navigate to Parking Place Detector → Settings → Locations & Cameras, select the location and click the blue Edit button. Fill in the Display Text field — see Fig.13 Parking Place Detector.

The data codes available for the Parking Place Detector module are:

Example (each line on its own row, as shown in the screenshot above):

#GAvailable #FSPACES2
#ROccupied #BSPACES2
#WTotal #TSPACES2

The screenshot uses #V on the last line, which the Nano Station shows in white with the letter in front — use #W or another colour from Section 6.1.

The auto-generated URL has the form:

http://IP_OF_THIS_SERVER/io/ppd/location_display.php?id=1

The same Display Text mechanism can also be applied at the Group level. For full details refer to the Parking Place Detector – Settings chapter of the Metrici Web Interface manual.

6.6 Quick Checklist

  1. In the Web Interface, fill in the Display Text field of the relevant module using colour codes and data codes, and save.
  2. Copy the auto-generated URL from the same page and replace IP_OF_THIS_SERVER with your Metrici server address.
  3. On the Nano Station, click or tap the Metrici logo 8 times and log in. In Display Settings, set Content Source to External URL (central API), paste the URL into Content URL and set Refresh Rate (typically 1 second).
  4. Click Save Display Settings, then Test Connection (saved URL). Last Refresh should show OK (HTTP 200) and On the Screen the expected lines.
  5. Check the Admin Activity Logs: the new DISPLAY_SETTINGS entry should show the URL you entered.

7. Tips & Troubleshooting

The screen shows "No signal"

The screen switches itself off after a while

The values on the screen do not change

A line is missing, white, or starts with an extra letter

The screen stopped updating after switching to Static IP

The numbers are wrong

Cannot open the admin panel or log in

General tips