User Manual for End Users and System Administrators
Drag to rotate • Scroll to zoom • Right-click to move
Overview
This manual explains how to install and operate the Metrici Nano Station — a compact player that connects to any TV, monitor or display through HDMI and shows live parking information from the Metrici Web Interface. It covers the hardware and its ports, first boot, the main display page, the password-protected admin panel and the settings you need in the Metrici Web Interface to drive the screen.
Introduction
The Metrici Nano Station turns any screen with an HDMI input — a TV, a computer monitor, a professional signage display or a large-format screen — into a live parking information sign. It reads the Display Text configured in the Metrici Web Interface (for example total, free and occupied parking spaces) and shows it full screen, with each line in its own colour and the Metrici logo at the top — see Fig.1 Main Page.
The device is built on a Raspberry Pi Compute Module housed in the official metal Raspberry Pi IO Case. Because you choose the screen, the same Nano Station can drive a small monitor at a pay station or a large TV at a car-park entrance.
Nano Station or RGB LED Display?
Metrici offers two ways of showing the same Web Interface data. Both read the same Display Text and the same display URLs, so a location can be switched from one to the other without changing anything in the Web Interface.
Metrici Nano Station
Metrici RGB LED Display
Screen
Any HDMI TV, monitor or display you choose
Built-in RGB LED matrix (64 × 32 or 128 × 64 pixels)
Installation
Indoor, next to or behind the screen
Indoor or outdoor, IP66 aluminium housing
Content
Display Text from the Metrici Web Interface, or fixed text
Display Text from the Metrici Web Interface, or fixed text
Configuration
On the connected screen — click or tap the Metrici logo 8 times to open the password-protected admin page
Browser-based configuration on port 3000, from any device on the network
Free-space information on a TV at a car-park entrance, in a lobby or next to a pay station, driven by the Parking for LPR module.
Per-level or per-zone screens in multi-storey car parks and shopping centres, driven by the Parking Place Detector.
Overview screens in control rooms and at reception desks showing total, free and occupied spaces.
Occupancy screens for areas monitored by Area Counter or Line Counter.
Technical Data
Specification
Details
Description
Compact HDMI player for Metrici parking and counting information
Enclosure
Raspberry Pi IO Case — two-piece sheet-metal enclosure with built-in, speed-controlled cooling fan
Video output
2 × full-size HDMI 2.0 (either port can be used)
USB
2 × USB 3.0 Type-A
Networking
1 × Gigabit Ethernet (RJ45); DHCP by default, static IP configurable
Power
USB-C, 5 V / 5 A (27 W)
Dimensions
170 × 94 × 28 mm
Content sources
External URL (display URL from the Metrici Web Interface, HTTP or HTTPS) or Internal text typed on the device
Text
Up to 3 lines, 7 colours (red, green, yellow, white, blue, cyan, magenta)
Software
Version 3.0
Configuration
Password-protected admin page on the connected screen, opened by clicking or tapping the Metrici logo 8 times; USB mouse or touchscreen, on-screen keyboard included
Installation
Indoor use, in a ventilated location
Ports & Connectors
All connectors are reached through the cut-outs in the side of the case. No connection requires opening the enclosure.
Connector
Qty
Use
HDMI
2
Video output to the screen. Connect the screen to either HDMI port — both work.
USB 3.0 Type-A
2
USB mouse (or the USB touch cable of a touchscreen) for configuring the device on the connected screen. A keyboard is optional — the login page has an on-screen keyboard.
Ethernet (RJ45)
1
Network connection to the Metrici server that provides the display data. The device obtains its IP address by DHCP.
USB-C
1
Power input (5 V / 5 A).
microSD slot
1
Reserved for service. Do not remove or replace the card unless instructed by Metrici support.
Note: The case has ventilation openings for its internal fan. Keep them unobstructed — do not seal the Nano Station inside a closed box or press it flat against the back of a screen without an air gap.
1. How Does It Work
The Nano Station does not calculate any values itself; it displays what the Metrici Web Interface publishes. The chain is:
Metrici Web Interface — a module such as Parking for LPR keeps track of the location (total spaces, vehicles inside, free spaces).
Display Text — in the location settings you decide what the screen should show, line by line, using colour codes and data codes (e.g. #GFREE: #FSPACES).
Display URL — the Web Interface publishes the result at an auto-generated address such as http://<METRICI_SERVER_IP>/io/lpr/location_display.php?id=1.
Nano Station — reads this URL at the configured refresh rate and draws the text full screen on the HDMI display.
When no Metrici server is involved, the Nano Station can instead show fixed text configured on the device itself (the Internal text source, see Section 5.2 – Display Settings).
2. Getting Started
2.1 Installation
Mount the screen and place the Nano Station close to it — for example behind the TV or in a nearby ventilated cabinet — within reach of the HDMI cable.
Connect an HDMI cable from the Nano Station to the screen and select that HDMI input on the screen.
Connect the Ethernet cable to a network with a DHCP server, from which the Metrici server is reachable. The Nano Station obtains its IP address automatically.
If the screen is not a touchscreen, connect a USB mouse to one of the USB ports — you need it to open and use the admin panel. For a touchscreen, connect its USB touch cable instead.
Connect the USB-C power supply last. The Nano Station starts up and opens the main display page full screen automatically.
Tip: Connect and switch on the screen before powering the Nano Station, so that the screen's resolution is detected correctly at start-up.
2.2 Opening the Admin Panel
The Nano Station is configured directly on the screen it is connected to:
Wait until the main page is shown on the screen.
Click (with the USB mouse) or tap (on a touchscreen) the Metrici logo at the top of the screen 8 times — marked 1 in Fig.1 Main Page.
The Admin Login page opens. Enter the admin password (default: metriciadmin) — see Section 4 – Admin Login.
No physical keyboard is needed: the login page includes an on-screen keyboard.
2.3 Network
The Nano Station comes configured for DHCP: it receives its IP address automatically from the network it is connected to. If the installation requires a fixed IP address, switch to Static IP in the admin panel — see Section 5.1 – Network Settings.
We recommend changing the default password immediately after the first login, to prevent unauthorised changes to what the screen displays. See Section 5.3 – Security Settings.
3. Main Page
Fig.1 Main Page – Live Parking Display
The main page is what the Nano Station shows on the connected screen during normal operation — see Fig.1 Main Page.
Metrici logo (marked 1) — shown at the top of the screen. It is also the way into the admin panel: click or tap it 8 times to open the Admin Login page (see Section 2.2).
Content lines — up to 3 lines; each line of the Display Text is drawn on its own row, in large text, in the colour given by its colour code. In the example above, the three lines are rendered in white (#W), green (#G) and red (#R).
Live values — the numbers are refreshed automatically at the configured refresh rate (for example every second), so the screen follows the parking occupancy in real time.
The example in Fig.1 is produced by the Display Text shown in Fig.10 Parking for LPR: a location with 5001 parking spaces and 1760 cars inside, leaving 3241 spaces free.
4. Admin Login
Fig.2 Admin Login
The Admin Login page opens after you click or tap the Metrici logo 8 times on the main page (see Section 2.2). Access to the admin panel is protected by a single admin password — see Fig.2 Admin Login. There is no username field.
Password — click the field and type the admin password. The default password is metriciadmin.
Login — opens the admin panel.
Show/Hide Keyboard — displays or hides an on-screen keyboard. Use it to type the password with the mouse or by touch when no physical keyboard is connected.
← Back to Main Page — returns to the live display without logging in.
5. Admin Panel
After logging in you reach the Admin Dashboard. The software version and build date are shown next to the title (for example v3.0 - 20261021). The dashboard is divided into panels for the network, the display content, the admin password, system management and the activity log. The ← Back to Main Page link at the bottom of the page returns to the live display.
The upper part of the panel shows the values the device is using right now:
Interface — the network interface in use, normally eth0 (the Ethernet port).
Network Mode — how the address is obtained, e.g. Dhcp.
NetworkManager Status — the connection state, e.g. connected.
IP Address, Netmask, Gateway, DNS Servers — the current network parameters. The IP address is the one to use when you need to find the Nano Station on the network.
MAC Address — the hardware address of the Ethernet port. You can use it to reserve a fixed address for the Nano Station in your router's DHCP settings.
As the note in the panel explains, these values are read live from the system. Network settings are applied through NetworkManager rather than stored in the Nano Station's settings database, and they are kept after Reboot System or a power cut.
DHCP
DHCP is the factory setting. With Network Mode set to DHCP, only three fields are shown — see Fig.3 Network Settings – DHCP:
Network Mode (1) — DHCP: the Nano Station receives its address automatically from the network.
Network Interface (2) — the interface to configure. Leave eth0 for the Ethernet port.
Connection UUID (optional) (3) — the identifier of the NetworkManager connection. Leave it empty to detect the connection for the interface automatically.
To go back to DHCP from a static address, select DHCP and click Apply Network Settings.
Fig.4 Network Settings – Static IP
Static IP
Select Static IP in Network Mode (1) and four more fields appear — see Fig.4 Network Settings – Static IP. Fields 2 and 3 work as described for DHCP.
IP Address (4) — the static IPv4 address of the Nano Station (e.g. 192.168.100.133).
Netmask (5) — the subnet mask (e.g. 255.255.255.0).
Gateway (6) — the default gateway (e.g. 192.168.100.1).
DNS Servers (7) — the DNS server (e.g. 192.168.100.1). Required when the Content URL uses a host name instead of an IP address.
Click Apply Network Settings, then check the Current Live Configuration to confirm the new values. The static address is kept after a restart or a power cut.
Important:
Before applying a static IP, make sure the address is not used by another device and is in the same subnet as the gateway. Otherwise the Nano Station cannot reach the Metrici server and the screen stops updating.
5.2 Display Settings
The Display Settings panel defines what the main page shows. The upper part, Current Configuration, shows what is saved and what the screen is doing; the form below it changes the settings.
Fig.5 Display Settings – External URL
Current Configuration
Content Source — External URL or Internal text.
Content URL — the URL the screen reads its content from.
Refresh Rate — how often the content is reloaded, in seconds.
Screen is doing — what the screen is doing right now, e.g. polls every 1 s, last poll 0 s ago (HTTP 200).
Last Refresh — the result and time of the last refresh, e.g. OK (HTTP 200) at 2026-10-26 09:53:06. HTTP 200 means the URL answered correctly.
On the Screen — a preview of the lines in their colours: with External URL, what the screen last received; with Internal text, the saved internal text.
Last Payload — the raw text last received from the URL, e.g. #BEGIN#WTOTAL: 5001#GFREE: 3241#RBUSY: 1760. Use it to check exactly what the Metrici Web Interface sends.
Content URL (2) — the display URL copied from the Metrici Web Interface, e.g. https://<server_IP>/io/lpr/location_display.php?id=1. Both http:// and https:// addresses can be used. The URL must return #BEGIN followed by one entry per text line, each starting with the initial of its colour — the display URLs of the Metrici Web Interface return exactly this. See Section 6 – Web Application Integration.
Refresh Rate (seconds) (3) — how often the screen asks the URL for new text. A value of 1 means every second.
Save Display Settings (4) — saves the settings.
Test Connection (saved URL) (5) — checks the Content URL that is currently saved. If you have just changed the URL, save it first, then test.
Content Source (1) — select Internal text (typed here).
Internal Text (2) — the text to show, one entry per line. The first letter of each entry is its colour (see Section 6.1 – Colour Codes) and the rest of the entry is the text. For example:
#RMetrici
#YAccurate
#BRecognition
shows Metrici in red, Accurate in yellow and Recognition in blue. The # key also separates entries, so the same text can be typed on a single line: #RMetrici#YAccurate#BRecognition. Up to 3 lines are shown.
Click Save Display Settings to apply the text.
Every saved change is recorded in the Admin Activity Logs as a DISPLAY_SETTINGS entry, together with the new source, URL or text, and refresh rate.
5.3 Security Settings
Fig.7 Security Settings
The Security Settings panel changes the admin password used on the login page — see Fig.7 Security Settings. The Nano Station ships with the default password metriciadmin; change it after the first login.
New Admin Password — type the new password.
Update Password — saves the new password. From then on, the new password is required to log in.
Important – Save your new password in a safe place!
Write the new password down or store it in a password manager before logging out. If the password is lost, contact Metrici support at support@metrici.ro.
5.4 System Management
Fig.8 System Management
The red Reboot System button restarts the Nano Station — see Fig.8 System Management. During the restart the screen goes blank or shows the start-up sequence; after a short time the main page opens again automatically with the saved settings.
Use it if the screen stops updating, or after reconnecting a screen that was not detected correctly.
Prefer Reboot System over unplugging the power: a controlled restart protects the device's storage.
Important:
Do not disconnect the power while the device is restarting. Wait until the main page appears on the screen again before opening the admin panel.
5.5 Admin Activity Logs
Fig.9 Admin Activity Logs
The Admin Activity Logs panel keeps a history of the changes made from the admin panel, newest first — see Fig.9 Admin Activity Logs. Each entry shows:
Event type — the area that was changed, for example DISPLAY_SETTINGS.
Date and time — when the change was saved (e.g. 2026-10-22 16:17:42).
Description — a short summary, for example Display settings updated.
Details — the values that were saved, for example source=external url=https://<server>/io/lpr/location_display.php?id=1 refresh_rate=1s or source=internal text=#BEGIN#RMetrici#YAccurate#BRecognition refresh_rate=1s.
Admin and IP — the admin account that made the change and the IP address recorded with it (e.g. Admin: admin | IP: 192.168.100.9).
Scroll inside the panel to see older entries. The Clear All Logs button deletes every entry in the list.
Tip:
The Details line is the quickest way to check which URL or text was saved last, and when.
6. Web Application Integration
When the Display Settings content source is External URL, the content of the screen is generated by a module of the Metrici Web Interface (Parking for LPR, Parking Place Detector, Area Counter, Line Counter). For each module you have to do two things:
In the Web Interface, fill in the Display Text field with the codes that describe what should appear on the screen.
Copy the auto-generated URL shown under the Display Text field and paste it into the Content URL field of the Nano Station (see Section 5.2 – Display Settings), replacing IP_OF_THIS_SERVER with the address of your Metrici server.
The Display Text uses two kinds of codes: colour codes (# followed by a letter) and data codes (# followed by the name of the value). Write each line of the screen on its own row of the Display Text field, starting with its colour code.
The Web Interface sends the result to the Nano Station as one text that starts with #BEGIN, followed by one entry per line — for example #BEGIN#WTOTAL: 5001#GFREE: 3241#RBUSY: 1760. You can see exactly what was received in the Last Payload field of the Display Settings panel.
6.1 Colour Codes
Each line starts with a colour code: # followed by the initial of the colour. The Nano Station recognises the following colours:
#R – Red
#G – Green
#Y – Yellow
#W – White
#B – Blue
#C – Cyan
#M – Magenta
Important:
The Nano Station shows up to 3 lines. An entry that starts with any other letter is shown in white exactly as typed, including that letter. The Web Interface help text also lists orange (#O), indigo (#I) and violet (#V) for the RGB LED Display; on the Nano Station these lines appear in white with the letter in front (for example #OFree is shown as OFree). For a Nano Station, use only R, G, Y, W, B, C and M.
A number from 1 to 9 may be appended to a data code to define how many characters are reserved for that value (for example, #COUNTER3 reserves three characters).
6.2 Parking Module for LPR
Fig.10 Parking for LPR – Display Text configuration
In the Web Interface navigate to Parking for LPR → Settings, select the location and click Edit Parking Settings. Fill in the Display Text field (marked 1) — see Fig.10 Parking for LPR.
The data codes available for the Parking module are:
#TSPACES – total number of parking spaces.
#BSPACES – number of occupied (busy) parking spaces.
#FSPACES – number of available (free) parking spaces.
Example — the Display Text that produces the screen in Fig.1 Main Page:
Copy this URL into the Content URL field of the Nano Station and click Save in the Web Interface. For full details refer to the Parking Module for LPR – Settings chapter of the Metrici Web Interface manual.
6.3 Area Counter
Fig.11 Area Counter – Edit Location
In the Web Interface navigate to Area Counter → Settings → Locations & Cameras, select the location and click the blue Edit button. Fill in the Display Text field — see Fig.11 Area Counter.
The data codes available for the Area Counter module are:
The same Display Text mechanism can also be applied at the Group level (a group is a collection of zones sharing a characteristic). For full details refer to the Area Counter – Settings chapter of the Metrici Web Interface manual.
6.4 Line Counter
Fig.12 Line Counter – Edit Zone
In the Web Interface navigate to Line Counter → Settings, select the location and the zone you want to edit, then click Edit Zone. Fill in the Display Text field — see Fig.12 Line Counter.
The data codes available for the Line Counter module are:
#CAPACITY – total capacity of the zone.
#COUNTER – current number of objects inside the zone.
#AVAILABLE – number of available slots.
#OCCUPANCY – occupancy level expressed as a percentage.
For full details refer to the Line Counter – Settings chapter of the Metrici Web Interface manual.
6.5 Parking Place Detector
Fig.13 Parking Place Detector – Edit Location
In the Web Interface navigate to Parking Place Detector → Settings → Locations & Cameras, select the location and click the blue Edit button. Fill in the Display Text field — see Fig.13 Parking Place Detector.
The data codes available for the Parking Place Detector module are:
#TSPACES – total number of parking spaces.
#BSPACES – number of occupied parking spaces.
#FSPACES – number of free parking spaces.
Example (each line on its own row, as shown in the screenshot above):
The same Display Text mechanism can also be applied at the Group level. For full details refer to the Parking Place Detector – Settings chapter of the Metrici Web Interface manual.
6.6 Quick Checklist
In the Web Interface, fill in the Display Text field of the relevant module using colour codes and data codes, and save.
Copy the auto-generated URL from the same page and replace IP_OF_THIS_SERVER with your Metrici server address.
On the Nano Station, click or tap the Metrici logo 8 times and log in. In Display Settings, set Content Source to External URL (central API), paste the URL into Content URL and set Refresh Rate (typically 1 second).
Click Save Display Settings, then Test Connection (saved URL). Last Refresh should show OK (HTTP 200) and On the Screen the expected lines.
Check the Admin Activity Logs: the new DISPLAY_SETTINGS entry should show the URL you entered.
7. Tips & Troubleshooting
The screen shows "No signal"
Check that the Nano Station is powered and that the HDMI cable is firmly connected at both ends.
Check that the screen is set to the HDMI input the cable is connected to.
Try the other HDMI port on the Nano Station — either port can be used.
If the screen was connected or switched on after the Nano Station, restart the Nano Station (Reboot System) so the screen is detected.
The screen switches itself off after a while
Many TVs have energy-saving timers (auto power off, sleep timer, standby on no activity). Disable them in the screen's own menu so the display stays on permanently.
The values on the screen do not change
In Display Settings, check Last Refresh and Screen is doing. OK (HTTP 200) means the URL answers correctly; any other status means the URL is wrong or the server cannot be reached. Use Test Connection (saved URL) after correcting it.
In Network Settings, check that NetworkManager Status is connected and that an IP address is shown.
Open the display URL in a browser on a computer in the same network as the Nano Station. If the page does not load, the Metrici server is not reachable or the URL is wrong.
Check in the Admin Activity Logs which URL and refresh rate were saved last.
Check the network cable and that the Nano Station's network allows access to the Metrici server (firewall, VLAN, HTTPS certificate).
Check that the network has a DHCP server that gives the Nano Station an IP address (for example in the router's list of connected devices).
A line is missing, white, or starts with an extra letter
Only the first 3 lines are shown — keep the Display Text to 3 lines.
Use only the colour codes #R, #G, #Y, #W, #B, #C and #M. Any other letter (e.g. #O, #I, #V) is shown in white together with the text.
Check that the data codes are spelled exactly as listed for the module (e.g. #FSPACES, not #FREESPACES).
Check the Last Payload field in Display Settings to see exactly what the screen received.
The screen stopped updating after switching to Static IP
Check that the IP address is not used by another device and is in the same subnet as the gateway.
Check the Gateway and DNS Servers values — DNS is required when the Content URL uses a host name.
To test, set Network Mode back to DHCP and click Apply Network Settings.
The numbers are wrong
The Nano Station only displays what the Web Interface calculates. Check the location's Parking Spaces and Cars inside values (or the zone capacity and counters in the other modules).
Cannot open the admin panel or log in
Make sure you click or tap the Metrici logo itself, 8 times.
If the screen is not a touchscreen, check that a USB mouse is connected and the pointer moves. On a touchscreen, check that its USB touch cable is connected to the Nano Station.
Check the password carefully when typing it on the on-screen keyboard. If it has been lost, contact support@metrici.ro.
General tips
Keep the ventilation openings of the case free and avoid installing the device next to heat sources.
Use Reboot System rather than unplugging the power whenever a restart is needed.
Change the default admin password after installation and keep it in a safe place.